Part Number Hot Search : 
OH090U 106M35 MC74ACT RT334048 CD3031B 11EQ06 063JS9E BS616
Product Description
Full Text Search
 

To Download PBA100F Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Unit type
Ordering information
PBA100F
R
PBA 100
1 2 3
F
4
-5
5
-O
1Series name 2 Output wattage 3 Universal input 4 Output voltage 5 Optional C :with Coating G :Low leakage current (0.15mA max / ACIN 240V) E :Low leakage current and EMI class A (0.5mA max / ACIN 240V) T :Vertical terminal block J :Connector type (Only -24, -36, -48) R :with Remote ON/OFF N :with Cover (Only 24V UL508 pending) N1 :with DIN rail V :Output voltage setting potentiometer externally
Specification is changed at option. Please consult us details.
MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PBA100F-3R3 PBA100F-5 66 100 3.3V 20A 5V 20A PBA100F-9 94.5 9V 10.5A PBA100F-12 102 12V 8.5A PBA100F-15 105 15V 7A PBA100F-24 108 24V 4.5A PBA100F-36 100.8 36V 2.8A PBA100F-48 100.8 48V 2.1A
SPECIFICATIONS
MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] INPUT EFFICIENCY[%] PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 AC85 - 264 1f or DC120 - 370 (AC70 or DC100 optionally available *4) ACIN 100V 0.9typ 1.3typ ACIN 200V 0.5typ 0.7typ 50/60 (47 - 63) ACIN 100V 77typ 81typ ACIN 200V 79typ 84typ PBA100F-24 PBA100F-36 PBA100F-48
80typ 82typ
81typ 83typ
83typ 86typ
84typ 86typ
84typ 86typ
84typ 86typ
OUTPUT
ACIN 100V 0.98typ 0.99typ POWER FACTOR(Io=100%) ACIN 200V 0.87typ 0.93typ ACIN 100V 20typ (Io=100%) (At cold start) INRUSH CURRENT[A] ACIN 200V 40typ (Io=100%) (At cold start) LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1) VOLTAGE[V] 3.3 5 9 12 15 CURRENT[A] 20 20 10.5 8.5 7 LINE REGULATION[mV] 20max 20max 36max 48max 60max LOAD REGULATION[mV] 40max 40max 100max 100max 120max 0 to +50C *1 80max 80max 120max 120max 120max RIPPLE[mVp-p] -10 - 0C *1 140max 140max 160max 160max 160max 0 to +50C *1 120max 120max 150max 150max 150max RIPPLE NOISE[mVp-p] -10 - 0C *1 160max 160max 180max 180max 180max 0 to +50C 50max 50max 90max 120max 150max TEMPERATURE REGULATION[mV] -10 to +50C 60max 60max 120max 150max 180max DRIFT[mV] *2 20max 20max 36max 48max 60max START-UP TIME[ms] 350typ(ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.60 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 OUTPUT VOLTAGE SETTING[V] 3.20 - 3.40 4.90 - 5.20 8.70 - 9.30 11.5 - 12.5 14.5 - 15.5 OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
24 4.5 96max 150max 120max 160max 150max 180max 240max 290max 96max
36 2.8 144max 240max 150max 200max 250max 300max 360max 450max 144max
48 2.1 192max 240max 150max 200max 250max 300max 480max 600max 192max
19.2 - 27.0 23.5 - 24.5
28.8 - 39.0 35.5 - 36.5 43.0 - 50.0
39.0 - 53.0 47.0 - 49.0 58.0 - 65.0
5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 PROTECTION OVERVOLTAGE PROTECTION[V] 4.00 - 5.25 CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS REMOTE SENSING Optional (Only -3R3, -5 Option -K) REMOTE ON/OFF Optional (Required external power source) INPUT-OUTPUT -RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) ISOLATION OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max , ENVIRONMENT STORAGE TEMP. HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS SAFETY AND CONDUCTED NOISE NOISE REGULATIONS CE MARKING HARMONIC ATTENUATOR OTHERS CASE SIZE/WEIGHT COOLING METHOD -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max 19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input) Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Low Voltage Directive, EMC Directive Complies with IEC61000-3-2 32X93X147mm (without terminal block) (WXHXD) / 440g max (without cover) Convection
* Derating is required when operated with cover. * A sound may occur from power supply at peak loading. *4 Derating is required.Consult us for details.
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and FG. * Parallel operation with other model is not possible.
PBA-6


▲Up To Search▲   

 
Price & Availability of PBA100F

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X